Spatial units
AMR-Hub spatial input uses metres as its canonical linear unit. Building YAML must declare the current schema and unit at the document root:
schema_version: 1
coordinate_unit: m
building:
# ...
All wall, door, opening, content, and agent coordinates are metres. Distances, radii, clearances, offsets, wall thicknesses, and content dimensions are also metres. Topological room areas are square metres.
SpaceInputReader rejects unitless input and units other than m. It does not
infer units from coordinate magnitudes and does not convert non-canonical
building YAML at runtime.
Floorplan conversion
CAD files can use arbitrary or undeclared local units. Floorplan extraction configuration must therefore define the source conversion explicitly:
spatial_units:
source_unit: millimetres
units_per_metre: 1000.0
Extraction, correction rules, tolerances, and diagnostics remain in these source units. The YAML construction stage converts walls, doors, openings, content positions, and areas to metres and records the conversion provenance:
schema_version: 1
coordinate_unit: m
coordinate_provenance:
source_unit: millimetres
units_per_metre: 1000.0
The source-unit name is descriptive. units_per_metre is the authoritative
positive conversion factor. Units must never be inferred from the descriptive
name or from the apparent size of the floorplan.
Time and movement
length_of_timestep_in_seconds defines the number of seconds represented by
one simulation timestep. Under the current movement implementation:
agent_movement_speedis metres per simulation timestep, not metres per second;agent_interaction_radiusis metres;- task durations are integer simulation timesteps;
- changing timestep length requires corresponding review of movement speed and task-duration values.
This documents current behaviour. A future change to metres per second would require movement and travel-time calculations to apply timestep duration.
Migrating existing YAML
For hand-authored synthetic YAML already expressed in metres, add
schema_version: 1 and coordinate_unit: m without changing coordinates.
Do not label legacy CAD-derived coordinates as metres without conversion.
Instead, add spatial_units to the extraction configuration and regenerate the
YAML. Real floorplans, extraction configuration, and generated outputs must
remain inside the TRE or local ignored workspace and must not be committed.